{"id":80867,"date":"2024-01-14T13:21:00","date_gmt":"2024-01-14T13:21:00","guid":{"rendered":"https:\/\/www.electricity-magnetism.org\/calculo-do-transformador-relacao-de-espiras-e-espiras-por-volt\/"},"modified":"2024-01-20T10:09:04","modified_gmt":"2024-01-20T10:09:04","slug":"calculo-do-transformador-relacao-de-espiras-e-espiras-por-volt","status":"publish","type":"post","link":"https:\/\/www.electricity-magnetism.org\/pt-br\/calculo-do-transformador-relacao-de-espiras-e-espiras-por-volt\/","title":{"rendered":"C\u00e1lculo do Transformador &#8211; Rela\u00e7\u00e3o de Espiras e Espiras por Volt |"},"content":{"rendered":"<h2>Entendendo a Rela\u00e7\u00e3o de Espiras e Espiras por Volt em Transformadores<\/h2>\n<p>Transformadores s\u00e3o componentes passivos essenciais na transfer\u00eancia de energia el\u00e9trica entre circuitos, desempenhando um papel crucial na gera\u00e7\u00e3o, transmiss\u00e3o e distribui\u00e7\u00e3o de energia el\u00e9trica ao redor do mundo. Neste artigo, exploraremos os princ\u00edpios por tr\u00e1s dos transformadores, seus diversos tipos e suas amplas aplica\u00e7\u00f5es em nossa vida cotidiana.<\/p>\n<h2>Princ\u00edpios B\u00e1sicos dos Transformadores<\/h2>\n<p>Um transformador opera com base na indu\u00e7\u00e3o eletromagn\u00e9tica para transferir energia el\u00e9trica entre dois ou mais circuitos. Sua capacidade de alterar os n\u00edveis de tens\u00e3o entre os circuitos prim\u00e1rio e secund\u00e1rio \u00e9 fundamental para o funcionamento eficiente dos sistemas de energia modernos.<\/p>\n<h2>Tipos e Aplica\u00e7\u00f5es dos Transformadores<\/h2>\n<p>Existem diversos tipos de transformadores, cada um projetado para aplica\u00e7\u00f5es espec\u00edficas. Eles variam desde pequenos transformadores em eletr\u00f4nicos at\u00e9 grandes unidades usadas em subesta\u00e7\u00f5es de energia. Suas aplica\u00e7\u00f5es incluem desde o carregamento de dispositivos port\u00e1teis at\u00e9 a alimenta\u00e7\u00e3o de grandes cidades.<\/p>\n<h2>Calculando a Rela\u00e7\u00e3o de Espiras e Espiras por Volt em Transformadores<\/h2>\n<p>Calcular um transformador envolve determinar suas especifica\u00e7\u00f5es com base nas tens\u00f5es de entrada e sa\u00edda requeridas, corrente e pot\u00eancia. Os par\u00e2metros cr\u00edticos incluem a rela\u00e7\u00e3o de espiras, o n\u00famero de espiras nas bobinas prim\u00e1ria e secund\u00e1ria e o tamanho do fio.<\/p>\n<h2>Rela\u00e7\u00e3o de Espiras<\/h2>\n<p>A rela\u00e7\u00e3o de espiras \u00e9 a raz\u00e3o entre o n\u00famero de espiras na bobina prim\u00e1ria (N<sub>p<\/sub>) e na bobina secund\u00e1ria (N<sub>s<\/sub>). Ela determina a rela\u00e7\u00e3o entre as tens\u00f5es de entrada (prim\u00e1ria) e sa\u00edda (secund\u00e1ria) de um transformador. A rela\u00e7\u00e3o de espiras pode ser expressa como:<\/p>\n<p>Rela\u00e7\u00e3o de Espiras (N) = N<sub>p<\/sub> \/ N<sub>s<\/sub><\/p>\n<p>De acordo com a equa\u00e7\u00e3o b\u00e1sica de tens\u00e3o de um transformador, a raz\u00e3o entre a tens\u00e3o prim\u00e1ria (V<sub>p<\/sub>) e a tens\u00e3o secund\u00e1ria (V<sub>s<\/sub>) \u00e9 igual \u00e0 rela\u00e7\u00e3o de espiras:<\/p>\n<p>V<sub>p<\/sub> \/ V<sub>s<\/sub> = N<sub>p<\/sub> \/ N<sub>s<\/sub><\/p>\n<h2>Espiras por Volt (Tpv)<\/h2>\n<p>Espiras por volt \u00e9 um par\u00e2metro usado no projeto de transformadores que representa o n\u00famero de espiras necess\u00e1rias na bobina para cada volt de sa\u00edda. Ele depende do material do n\u00facleo, do tamanho do n\u00facleo e da frequ\u00eancia de opera\u00e7\u00e3o. A f\u00f3rmula para calcular as espiras por volt \u00e9:<\/p>\n<p>Tpv = (4,44 * 10<sup>4<\/sup> * Ae * Bm * f) \/ V<sub>p<\/sub><\/p>\n<p>Onde:<\/p>\n<ul>\n<li>Ae \u00e9 a \u00e1rea da se\u00e7\u00e3o transversal efetiva do n\u00facleo (cm\u00b2 ou m\u00b2)<\/li>\n<li>Bm \u00e9 a densidade de fluxo magn\u00e9tico m\u00e1xima do material do n\u00facleo (T, Tesla)<\/li>\n<li>f \u00e9 a frequ\u00eancia de opera\u00e7\u00e3o (Hz)<\/li>\n<li>V<sub>p<\/sub> \u00e9 a tens\u00e3o prim\u00e1ria (V)<\/li>\n<\/ul>\n<h2>Exemplo de C\u00e1lculo<\/h2>\n<p>Considere o projeto de um transformador monof\u00e1sico rebaixador que converte uma tens\u00e3o de entrada AC de 240V para uma tens\u00e3o de sa\u00edda AC de 12V, com uma pot\u00eancia de 120W.<\/p>\n<p>Passo 1: Determine a rela\u00e7\u00e3o de espiras. N = V<sub>p<\/sub> \/ V<sub>s<\/sub>. Neste exemplo, N = 240V \/ 12V = 20.<\/p>\n<p>Passo 2: Calcule as correntes prim\u00e1ria e secund\u00e1ria. Para o lado prim\u00e1rio (I<sub>p<\/sub>): I<sub>p<\/sub> = P \/ V<sub>p<\/sub>. I<sub>p<\/sub> = 120W \/ 240V = 0,5A. Para o lado secund\u00e1rio (I<sub>s<\/sub>): I<sub>s<\/sub> = P \/ V<sub>s<\/sub>. I<sub>s<\/sub> = 120W \/ 12V = 10A.<\/p>\n<p>Passo 3: Selecione o tamanho do n\u00facleo e calcule o n\u00famero de espiras. Supondo um Bm de 1,1 T para o material do n\u00facleo e uma \u00e1rea de se\u00e7\u00e3o transversal (Ae) de 1,5 cm\u00b2: Tpv = (4,44 * 10<sup>4<\/sup> * 1,5 * 1,1 * 50) \/ 240V = 1,375 espiras\/volt. Agora, podemos calcular o n\u00famero de espiras nas bobinas prim\u00e1ria e secund\u00e1ria.<\/p>\n<p>Bobina prim\u00e1ria (N<sub>p<\/sub>): N<sub>p<\/sub> = V<sub>p<\/sub> * Tpv. N<sub>p<\/sub> \u2248 330 espiras.<\/p>\n<p>Bobina secund\u00e1ria (N<sub>s<\/sub>): N<sub>s<\/sub> = V<sub>s<\/sub> * Tpv. N<sub>s<\/sub> \u2248 16 espiras.<\/p>\n<p>Em resumo, a rela\u00e7\u00e3o de espiras \u00e9 essencial para entender a transforma\u00e7\u00e3o de tens\u00e3o entre os lados prim\u00e1rio e secund\u00e1rio de um transformador, enquanto espiras por volt \u00e9 um par\u00e2metro cr\u00edtico no projeto de transformadores, ajudando a determinar o n\u00famero apropriado de espiras nas bobinas.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.electricity-magnetism.org\/wp-content\/uploads\/2022\/01\/logo.png\" alt=\"\" \/><\/p>\n<div style=\"text-align: center; font-size: 20px;\">\n    <a href=\"https:\/\/www.electricity-magnetism.org\/calculation-of-transformer-turns-ratio-turns-per-volt\/\">Original Article<\/a>\n<\/div>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Para o c\u00e1lculo de um transformador, os par\u00e2metros mais cr\u00edticos incluem a rela\u00e7\u00e3o de espiras, espiras por volt e o tamanho do fio.<\/p>\n","protected":false},"author":1,"featured_media":1581,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_generate-full-width-content":"","footnotes":""},"categories":[14],"tags":[],"class_list":["post-80867","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-nao-categorizado","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v17.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>C\u00e1lculo do Transformador - Rela\u00e7\u00e3o de Espiras e Espiras por Volt |<\/title>\n<meta name=\"description\" content=\"Para o c\u00e1lculo de um transformador, os par\u00e2metros mais cr\u00edticos incluem a rela\u00e7\u00e3o de espiras, espiras por volt e o tamanho do fio.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.electricity-magnetism.org\/pt-br\/calculo-do-transformador-relacao-de-espiras-e-espiras-por-volt\/\" \/>\n<meta property=\"og:locale\" content=\"pt_BR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"C\u00e1lculo do Transformador - Rela\u00e7\u00e3o de Espiras e Espiras por Volt |\" \/>\n<meta property=\"og:description\" content=\"Para o c\u00e1lculo de um transformador, os par\u00e2metros mais cr\u00edticos incluem a rela\u00e7\u00e3o de espiras, espiras por volt e o tamanho do fio.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.electricity-magnetism.org\/pt-br\/calculo-do-transformador-relacao-de-espiras-e-espiras-por-volt\/\" \/>\n<meta property=\"og:site_name\" content=\"Electricity - Magnetism\" \/>\n<meta property=\"article:published_time\" content=\"2024-01-14T13:21:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-01-20T10:09:04+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.electricity-magnetism.org\/wp-content\/uploads\/2022\/01\/logo.png\" \/>\n\t<meta property=\"og:image:width\" content=\"200\" \/>\n\t<meta property=\"og:image:height\" content=\"200\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Matan\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. tempo de leitura\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.electricity-magnetism.org\/pt-br\/#website\",\"url\":\"https:\/\/www.electricity-magnetism.org\/pt-br\/\",\"name\":\"Electricity - Magnetism\",\"description\":\"All about electricity and magnetism.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.electricity-magnetism.org\/pt-br\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"pt-BR\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.electricity-magnetism.org\/pt-br\/calculo-do-transformador-relacao-de-espiras-e-espiras-por-volt\/#primaryimage\",\"inLanguage\":\"pt-BR\",\"url\":\"https:\/\/www.electricity-magnetism.org\/wp-content\/uploads\/2022\/01\/logo.png\",\"contentUrl\":\"https:\/\/www.electricity-magnetism.org\/wp-content\/uploads\/2022\/01\/logo.png\",\"width\":200,\"height\":200,\"caption\":\"Eletromagnetismo\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.electricity-magnetism.org\/pt-br\/calculo-do-transformador-relacao-de-espiras-e-espiras-por-volt\/#webpage\",\"url\":\"https:\/\/www.electricity-magnetism.org\/pt-br\/calculo-do-transformador-relacao-de-espiras-e-espiras-por-volt\/\",\"name\":\"C\\u00e1lculo do Transformador - Rela\\u00e7\\u00e3o de Espiras e Espiras por Volt |\",\"isPartOf\":{\"@id\":\"https:\/\/www.electricity-magnetism.org\/pt-br\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.electricity-magnetism.org\/pt-br\/calculo-do-transformador-relacao-de-espiras-e-espiras-por-volt\/#primaryimage\"},\"datePublished\":\"2024-01-14T13:21:00+00:00\",\"dateModified\":\"2024-01-20T10:09:04+00:00\",\"author\":{\"@id\":\"https:\/\/www.electricity-magnetism.org\/pt-br\/#\/schema\/person\/68f28ba0ad08ef355b436c5222a40b29\"},\"description\":\"Para o c\\u00e1lculo de um transformador, os par\\u00e2metros mais cr\\u00edticos incluem a rela\\u00e7\\u00e3o de espiras, espiras por volt e o tamanho do fio.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.electricity-magnetism.org\/pt-br\/calculo-do-transformador-relacao-de-espiras-e-espiras-por-volt\/#breadcrumb\"},\"inLanguage\":\"pt-BR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.electricity-magnetism.org\/pt-br\/calculo-do-transformador-relacao-de-espiras-e-espiras-por-volt\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.electricity-magnetism.org\/pt-br\/calculo-do-transformador-relacao-de-espiras-e-espiras-por-volt\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.electricity-magnetism.org\/pt-br\/electricity-magnetism-page\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"C\\u00e1lculo do Transformador &#8211; Rela\\u00e7\\u00e3o de Espiras e Espiras por Volt |\"}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.electricity-magnetism.org\/pt-br\/#\/schema\/person\/68f28ba0ad08ef355b436c5222a40b29\",\"name\":\"Matan\",\"url\":\"https:\/\/www.electricity-magnetism.org\/pt-br\/author\/matan\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"C\u00e1lculo do Transformador - Rela\u00e7\u00e3o de Espiras e Espiras por Volt |","description":"Para o c\u00e1lculo de um transformador, os par\u00e2metros mais cr\u00edticos incluem a rela\u00e7\u00e3o de espiras, espiras por volt e o tamanho do fio.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.electricity-magnetism.org\/pt-br\/calculo-do-transformador-relacao-de-espiras-e-espiras-por-volt\/","og_locale":"pt_BR","og_type":"article","og_title":"C\u00e1lculo do Transformador - Rela\u00e7\u00e3o de Espiras e Espiras por Volt |","og_description":"Para o c\u00e1lculo de um transformador, os par\u00e2metros mais cr\u00edticos incluem a rela\u00e7\u00e3o de espiras, espiras por volt e o tamanho do fio.","og_url":"https:\/\/www.electricity-magnetism.org\/pt-br\/calculo-do-transformador-relacao-de-espiras-e-espiras-por-volt\/","og_site_name":"Electricity - Magnetism","article_published_time":"2024-01-14T13:21:00+00:00","article_modified_time":"2024-01-20T10:09:04+00:00","og_image":[{"width":200,"height":200,"url":"https:\/\/www.electricity-magnetism.org\/wp-content\/uploads\/2022\/01\/logo.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"Matan","Est. tempo de leitura":"3 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebSite","@id":"https:\/\/www.electricity-magnetism.org\/pt-br\/#website","url":"https:\/\/www.electricity-magnetism.org\/pt-br\/","name":"Electricity - Magnetism","description":"All about electricity and magnetism.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.electricity-magnetism.org\/pt-br\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"pt-BR"},{"@type":"ImageObject","@id":"https:\/\/www.electricity-magnetism.org\/pt-br\/calculo-do-transformador-relacao-de-espiras-e-espiras-por-volt\/#primaryimage","inLanguage":"pt-BR","url":"https:\/\/www.electricity-magnetism.org\/wp-content\/uploads\/2022\/01\/logo.png","contentUrl":"https:\/\/www.electricity-magnetism.org\/wp-content\/uploads\/2022\/01\/logo.png","width":200,"height":200,"caption":"Eletromagnetismo"},{"@type":"WebPage","@id":"https:\/\/www.electricity-magnetism.org\/pt-br\/calculo-do-transformador-relacao-de-espiras-e-espiras-por-volt\/#webpage","url":"https:\/\/www.electricity-magnetism.org\/pt-br\/calculo-do-transformador-relacao-de-espiras-e-espiras-por-volt\/","name":"C\u00e1lculo do Transformador - Rela\u00e7\u00e3o de Espiras e Espiras por Volt |","isPartOf":{"@id":"https:\/\/www.electricity-magnetism.org\/pt-br\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.electricity-magnetism.org\/pt-br\/calculo-do-transformador-relacao-de-espiras-e-espiras-por-volt\/#primaryimage"},"datePublished":"2024-01-14T13:21:00+00:00","dateModified":"2024-01-20T10:09:04+00:00","author":{"@id":"https:\/\/www.electricity-magnetism.org\/pt-br\/#\/schema\/person\/68f28ba0ad08ef355b436c5222a40b29"},"description":"Para o c\u00e1lculo de um transformador, os par\u00e2metros mais cr\u00edticos incluem a rela\u00e7\u00e3o de espiras, espiras por volt e o tamanho do fio.","breadcrumb":{"@id":"https:\/\/www.electricity-magnetism.org\/pt-br\/calculo-do-transformador-relacao-de-espiras-e-espiras-por-volt\/#breadcrumb"},"inLanguage":"pt-BR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.electricity-magnetism.org\/pt-br\/calculo-do-transformador-relacao-de-espiras-e-espiras-por-volt\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.electricity-magnetism.org\/pt-br\/calculo-do-transformador-relacao-de-espiras-e-espiras-por-volt\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.electricity-magnetism.org\/pt-br\/electricity-magnetism-page\/"},{"@type":"ListItem","position":2,"name":"C\u00e1lculo do Transformador &#8211; Rela\u00e7\u00e3o de Espiras e Espiras por Volt |"}]},{"@type":"Person","@id":"https:\/\/www.electricity-magnetism.org\/pt-br\/#\/schema\/person\/68f28ba0ad08ef355b436c5222a40b29","name":"Matan","url":"https:\/\/www.electricity-magnetism.org\/pt-br\/author\/matan\/"}]}},"_links":{"self":[{"href":"https:\/\/www.electricity-magnetism.org\/pt-br\/wp-json\/wp\/v2\/posts\/80867","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.electricity-magnetism.org\/pt-br\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.electricity-magnetism.org\/pt-br\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.electricity-magnetism.org\/pt-br\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.electricity-magnetism.org\/pt-br\/wp-json\/wp\/v2\/comments?post=80867"}],"version-history":[{"count":0,"href":"https:\/\/www.electricity-magnetism.org\/pt-br\/wp-json\/wp\/v2\/posts\/80867\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.electricity-magnetism.org\/pt-br\/wp-json\/wp\/v2\/media\/1581"}],"wp:attachment":[{"href":"https:\/\/www.electricity-magnetism.org\/pt-br\/wp-json\/wp\/v2\/media?parent=80867"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.electricity-magnetism.org\/pt-br\/wp-json\/wp\/v2\/categories?post=80867"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.electricity-magnetism.org\/pt-br\/wp-json\/wp\/v2\/tags?post=80867"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}