{"id":146590,"date":"2024-03-21T14:08:04","date_gmt":"2024-03-21T14:08:04","guid":{"rendered":"https:\/\/www.electricity-magnetism.org\/equations-de-london-explication-utilite\/"},"modified":"2024-03-29T19:35:40","modified_gmt":"2024-03-29T19:35:40","slug":"equations-de-london-explication-utilite","status":"publish","type":"post","link":"https:\/\/www.electricity-magnetism.org\/fr\/equations-de-london-explication-utilite\/","title":{"rendered":"\u00c9quations de London | Explication &#038; Utilit\u00e9"},"content":{"rendered":"<p class=\"sidekick\">Comprenez les \u00e9quations de London et leur r\u00f4le cl\u00e9 dans la compr\u00e9hension de la supraconductivit\u00e9 et les avanc\u00e9es technologiques qu&rsquo;elles ont rendues possibles.<\/p>\n<h2>Introduction aux \u00c9quations de London<\/h2>\n<p>Les \u00e9quations de London, du nom des fr\u00e8res Fritz et Heinz London qui les ont formul\u00e9es en 1935, sont fondamentales pour comprendre la supraconductivit\u00e9 &#8211; une propri\u00e9t\u00e9 de certains mat\u00e9riaux \u00e0 conduire le courant \u00e9lectrique sans r\u00e9sistance ni perte d&rsquo;\u00e9nergie lorsqu\u2019ils sont refroidis en dessous d&rsquo;une temp\u00e9rature critique. Ces \u00e9quations d\u00e9crivent comment les champs \u00e9lectromagn\u00e9tiques se comportent \u00e0 l&rsquo;int\u00e9rieur des supraconducteurs.<\/p>\n<h2>Les \u00c9quations de Base<\/h2>\n<p>Il y a deux \u00e9quations de London qui se pr\u00e9sentent comme suit. La premi\u00e8re \u00e9quation de London est :<\/p>\n<p>\\[ \\frac{\\partial \\mathbf{J}}{\\partial t} = \\frac{n_s e^2}{m} \\mathbf{E} \\]<\/p>\n<p>o\u00f9 \\( \\mathbf{J} \\) est la densit\u00e9 de courant de supraconductivit\u00e9, \\( n_s \\) repr\u00e9sente la densit\u00e9 des \u00e9lectrons supraconducteurs, \\( e \\) est la charge \u00e9l\u00e9mentaire, \\( m \\) la masse de l&rsquo;\u00e9lectron et \\( \\mathbf{E} \\) le champ \u00e9lectrique.<\/p>\n<p>La deuxi\u00e8me \u00e9quation de London exprime la relation entre la densit\u00e9 de courant et le champ magn\u00e9tique \\( \\mathbf{B} \\):<\/p>\n<p>\\[ \\nabla \\times \\mathbf{J} = -\\frac{n_s e^2}{m} \\mathbf{B} \\]<\/p>\n<h2>Interpr\u00e9tation Physique<\/h2>\n<p>La premi\u00e8re \u00e9quation nous indique qu&rsquo;un champ \u00e9lectrique appliqu\u00e9 \u00e0 un supraconducteur produit un courant qui ne diminue pas avec le temps. Cela explique pourquoi la r\u00e9sistance est nulle &#8211; le courant peut circuler ind\u00e9finiment sans source de tension externe une fois qu&rsquo;il est \u00e9tabli.<\/p>\n<p>La deuxi\u00e8me \u00e9quation de London relie la variation spatiale de la densit\u00e9 du courant de supraconductivit\u00e9 et le champ magn\u00e9tique. Elle m\u00e8ne \u00e0 un ph\u00e9nom\u00e8ne connu sous le nom d&rsquo;effet Meissner, qui est la capacit\u00e9 d&rsquo;un supraconducteur \u00e0 expulser les champs magn\u00e9tiques de son int\u00e9rieur, les rendant des parfaits diamagn\u00e9tiques.<\/p>\n<h2>Utilit\u00e9 des \u00c9quations de London<\/h2>\n<p>L&rsquo;utilit\u00e9 des \u00e9quations de London r\u00e9side dans leur capacit\u00e9 \u00e0 d\u00e9crire quantitativement l&rsquo;\u00e9lectrodynamique des supraconducteurs. Elles permettent de pr\u00e9dire comment un courant supraconducteur va r\u00e9agir sous l&rsquo;influence de champs \u00e9lectriques et magn\u00e9tiques externes et vice-versa. Cela a de profondes implications dans les domaines de la recherche fondamentale et des applications pratiques, telles que:<\/p>\n<ul>\n<li><strong>Levitation Magn\u00e9tique:<\/strong> L&rsquo;effet Meissner expliqu\u00e9 par les \u00e9quations de London est la base th\u00e9orique derri\u00e8re la l\u00e9vitation des trains \u00e0 sustentation magn\u00e9tique, qui utilisent des supraconducteurs pour atteindre une l\u00e9vitation stable au-dessus des rails magn\u00e9tiques.<\/li>\n<li><strong>IRM (Imagerie par R\u00e9sonance Magn\u00e9tique):<\/strong> Les supraconducteurs jouent un r\u00f4le crucial dans les bobines d&rsquo;IRM, permettant de g\u00e9n\u00e9rer de puissants champs magn\u00e9tiques n\u00e9cessaires pour cette technique d&rsquo;imagerie m\u00e9dicale sans consommer une grande quantit\u00e9 d&rsquo;\u00e9nergie \u00e9lectrique.<\/li>\n<li><strong>Acc\u00e9l\u00e9rateurs de Particules:<\/strong> Les aimants supraconducteurs sont utilis\u00e9s dans les acc\u00e9l\u00e9rateurs de particules pour cr\u00e9er des champs magn\u00e9tiques tr\u00e8s intenses afin de guider et d&rsquo;acc\u00e9l\u00e9rer les particules \u00e0 des vitesses proches de celle de la lumi\u00e8re.<\/li>\n<\/ul>\n<h2>Conclusion<\/h2>\n<p>En r\u00e9sum\u00e9, les \u00e9quations de London sont essentielles pour d\u00e9crire la physique des supraconducteurs, et elles ont permis de nombreuses avanc\u00e9es technologiques. Bien que la th\u00e9orie des \u00e9quations de London ait \u00e9t\u00e9 supplant\u00e9e par la th\u00e9orie BCS (Bardeen-Cooper-Schrieffer) en termes de compr\u00e9hension compl\u00e8te de la supraconductivit\u00e9, l&rsquo;importance des \u00e9quations de London demeure en raison de leur simplicit\u00e9 et de leur capacit\u00e9 \u00e0 d\u00e9crire avec pr\u00e9cision de nombreux aspects comportementaux des supraconducteurs.<\/p>\n<p>L&rsquo;\u00e9tude des \u00e9quations de London continue de jouer un r\u00f4le fondamental dans le d\u00e9veloppement de technologies innovantes et a grandement contribu\u00e9 \u00e0 notre compr\u00e9hension de la mati\u00e8re \u00e0 l&rsquo;\u00e9chelle microscopique. C\u2019est un parfait exemple montrant comment des formules math\u00e9matiques peuvent mener \u00e0 des d\u00e9couvertes qui transforment notre monde.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Comprenez les \u00e9quations de London et leur r\u00f4le cl\u00e9 dans la compr\u00e9hension de la supraconductivit\u00e9 et les avanc\u00e9es technologiques qu&rsquo;elles ont rendues possibles.<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_generate-full-width-content":"","footnotes":""},"categories":[48],"tags":[49],"class_list":["post-146590","post","type-post","status-publish","format-standard","hentry","category-equations","tag-equations","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v17.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>\u00c9quations de London | Explication &amp; Utilit\u00e9<\/title>\n<meta name=\"description\" content=\"Comprenez les \u00e9quations de London et leur r\u00f4le cl\u00e9 dans la compr\u00e9hension de la supraconductivit\u00e9 et les avanc\u00e9es technologiques qu&#039;elles ont rendues possibles.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.electricity-magnetism.org\/fr\/equations-de-london-explication-utilite\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u00c9quations de London | Explication &amp; Utilit\u00e9\" \/>\n<meta property=\"og:description\" content=\"Comprenez les \u00e9quations de London et leur r\u00f4le cl\u00e9 dans la compr\u00e9hension de la supraconductivit\u00e9 et les avanc\u00e9es technologiques qu&#039;elles ont rendues possibles.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.electricity-magnetism.org\/fr\/equations-de-london-explication-utilite\/\" \/>\n<meta property=\"og:site_name\" content=\"Electricity - Magnetism\" \/>\n<meta property=\"article:published_time\" content=\"2024-03-21T14:08:04+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-03-29T19:35:40+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Matan\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.electricity-magnetism.org\/fr\/#website\",\"url\":\"https:\/\/www.electricity-magnetism.org\/fr\/\",\"name\":\"Electricity - Magnetism\",\"description\":\"All about electricity and magnetism.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.electricity-magnetism.org\/fr\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.electricity-magnetism.org\/fr\/equations-de-london-explication-utilite\/#webpage\",\"url\":\"https:\/\/www.electricity-magnetism.org\/fr\/equations-de-london-explication-utilite\/\",\"name\":\"\\u00c9quations de London | Explication & Utilit\\u00e9\",\"isPartOf\":{\"@id\":\"https:\/\/www.electricity-magnetism.org\/fr\/#website\"},\"datePublished\":\"2024-03-21T14:08:04+00:00\",\"dateModified\":\"2024-03-29T19:35:40+00:00\",\"author\":{\"@id\":\"https:\/\/www.electricity-magnetism.org\/fr\/#\/schema\/person\/68f28ba0ad08ef355b436c5222a40b29\"},\"description\":\"Comprenez les \\u00e9quations de London et leur r\\u00f4le cl\\u00e9 dans la compr\\u00e9hension de la supraconductivit\\u00e9 et les avanc\\u00e9es technologiques qu'elles ont rendues possibles.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.electricity-magnetism.org\/fr\/equations-de-london-explication-utilite\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.electricity-magnetism.org\/fr\/equations-de-london-explication-utilite\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.electricity-magnetism.org\/fr\/equations-de-london-explication-utilite\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.electricity-magnetism.org\/fr\/electricity-magnetism-page\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\\u00c9quations de London | Explication &#038; Utilit\\u00e9\"}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.electricity-magnetism.org\/fr\/#\/schema\/person\/68f28ba0ad08ef355b436c5222a40b29\",\"name\":\"Matan\",\"url\":\"https:\/\/www.electricity-magnetism.org\/fr\/author\/matan\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u00c9quations de London | Explication & Utilit\u00e9","description":"Comprenez les \u00e9quations de London et leur r\u00f4le cl\u00e9 dans la compr\u00e9hension de la supraconductivit\u00e9 et les avanc\u00e9es technologiques qu'elles ont rendues possibles.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.electricity-magnetism.org\/fr\/equations-de-london-explication-utilite\/","og_locale":"fr_FR","og_type":"article","og_title":"\u00c9quations de London | Explication & Utilit\u00e9","og_description":"Comprenez les \u00e9quations de London et leur r\u00f4le cl\u00e9 dans la compr\u00e9hension de la supraconductivit\u00e9 et les avanc\u00e9es technologiques qu'elles ont rendues possibles.","og_url":"https:\/\/www.electricity-magnetism.org\/fr\/equations-de-london-explication-utilite\/","og_site_name":"Electricity - Magnetism","article_published_time":"2024-03-21T14:08:04+00:00","article_modified_time":"2024-03-29T19:35:40+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"Matan","Dur\u00e9e de lecture estim\u00e9e":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebSite","@id":"https:\/\/www.electricity-magnetism.org\/fr\/#website","url":"https:\/\/www.electricity-magnetism.org\/fr\/","name":"Electricity - Magnetism","description":"All about electricity and magnetism.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.electricity-magnetism.org\/fr\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/www.electricity-magnetism.org\/fr\/equations-de-london-explication-utilite\/#webpage","url":"https:\/\/www.electricity-magnetism.org\/fr\/equations-de-london-explication-utilite\/","name":"\u00c9quations de London | Explication & Utilit\u00e9","isPartOf":{"@id":"https:\/\/www.electricity-magnetism.org\/fr\/#website"},"datePublished":"2024-03-21T14:08:04+00:00","dateModified":"2024-03-29T19:35:40+00:00","author":{"@id":"https:\/\/www.electricity-magnetism.org\/fr\/#\/schema\/person\/68f28ba0ad08ef355b436c5222a40b29"},"description":"Comprenez les \u00e9quations de London et leur r\u00f4le cl\u00e9 dans la compr\u00e9hension de la supraconductivit\u00e9 et les avanc\u00e9es technologiques qu'elles ont rendues possibles.","breadcrumb":{"@id":"https:\/\/www.electricity-magnetism.org\/fr\/equations-de-london-explication-utilite\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.electricity-magnetism.org\/fr\/equations-de-london-explication-utilite\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.electricity-magnetism.org\/fr\/equations-de-london-explication-utilite\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.electricity-magnetism.org\/fr\/electricity-magnetism-page\/"},{"@type":"ListItem","position":2,"name":"\u00c9quations de London | Explication &#038; Utilit\u00e9"}]},{"@type":"Person","@id":"https:\/\/www.electricity-magnetism.org\/fr\/#\/schema\/person\/68f28ba0ad08ef355b436c5222a40b29","name":"Matan","url":"https:\/\/www.electricity-magnetism.org\/fr\/author\/matan\/"}]}},"_links":{"self":[{"href":"https:\/\/www.electricity-magnetism.org\/fr\/wp-json\/wp\/v2\/posts\/146590","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.electricity-magnetism.org\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.electricity-magnetism.org\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.electricity-magnetism.org\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.electricity-magnetism.org\/fr\/wp-json\/wp\/v2\/comments?post=146590"}],"version-history":[{"count":0,"href":"https:\/\/www.electricity-magnetism.org\/fr\/wp-json\/wp\/v2\/posts\/146590\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.electricity-magnetism.org\/fr\/wp-json\/wp\/v2\/media?parent=146590"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.electricity-magnetism.org\/fr\/wp-json\/wp\/v2\/categories?post=146590"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.electricity-magnetism.org\/fr\/wp-json\/wp\/v2\/tags?post=146590"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}